Measured U-Value Loss, Fouling Resistance, Cooling Capacity, Cleaning Recovery, Temperature Profile & Lifecycle ROI

Marine Heat Exchanger Fouling, Cooling Capacity & Cleaning ROI Tool

Screen whether a marine cooler, condenser or process heat exchanger is losing enough heat-transfer performance to justify cleaning. Simple mode compares clean and current overall heat-transfer coefficients and links the recoverable fouling penalty to cleaning payback. Advanced mode calculates LMTD, measured U, fouling resistance, duty shortfall, post-clean recovery and lifecycle economics across multiple operating conditions.

Data type
Currency
Currency selection changes display only. No exchange-rate conversion is performed.
↑
Need measured thermal-performance detail? Click Advanced above.Add heat-transfer area, counterflow LMTD, multiple operating points, required duty, post-clean U recovery, pump/compressor energy penalty, thermal-shortfall value, cleaning downtime, degradation and lifecycle NPV.

Fast Fouling & Cleaning ROI Screen

Simple mode assumes current and post-clean duty scale approximately with U under comparable flow and temperature-driving-force conditions. Use Advanced when temperatures and operating conditions vary materially.

W/m²K.
W/m²K.
kW.
kW.
Selected currency / operating hour, including energy and lost-capacity effects.
Contractor, chemicals, labor and downtime if desired.
% of the current U-to-clean-U gap restored.
years.

Exchanger & Clean-Performance Basis

m².
W/m²K.
kW.
% of measured fouling gap restored.
kW attributed to fouling / restriction.
%.
Selected currency / kWh equivalent.
Selected currency / MWh-th recovered up to required duty.

Operating-Condition Register

Measured duty and four terminal temperatures are used to calculate LMTD and measured U. Keep temperatures and duty from the same stabilized operating period.

ConditionHours / yrHot in °CHot out °CCold in °CCold out °CMeasured duty kWRequired duty kW

Cleaning Strategy & Economics

hours.
Selected currency / hour.
%/year as fouling returns.
years.
years.
%.

Measurement & Cleaning Readiness

Thermal-performance screening only: this tool does not replace exchanger rating software, OEM cleaning instructions, tube/plate inspection, pressure-drop analysis, seawater-side corrosion assessment, material compatibility review or pressure-boundary inspection. Measured U can be distorted by unstable operation, bad flow estimates, temperature-sensor error, bypassing, air binding or flow maldistribution.
By the ShipUniverse Editorial Team — About Us | Contact