SHIPUNIVERSE
Maritime Intelligence, Tools & Live Industry Radars

One place for live maritime intelligence, practical decision tools, industry events and focused reporting.

15Live Radars 263Maritime Tools
24/7Intelligence Focus
GlobalIndustry Coverage
NEW RADARS

Explore our latest intelligence radars

RADARS
TOOLS
All Tools
Latest 20
Open to load latest items…
NEWS
All News
Latest 20
Open to load latest items…
REPORTS
All Reports
Latest 20
Open to load latest items…
TECH
All Tech
Latest 20
Open to load latest items…
CRUISE
All Cruise
Latest 20
Open to load latest items…
NAVAL
All Naval
Latest 20
Open to load latest items…

Fixed CO₂ Fire-Extinguishing Cylinder Quantity, Flooding Concentration & Release Time Tool

SOLAS II-2 • FSS Code Chapter 5 • CO₂ Quantity • Cylinder Bank • Flooding Time • Alarms • Controls • Maintenance

Fixed CO₂ Fire-Extinguishing Cylinder Quantity, Flooding Concentration & Release Time Tool

Screen required free-gas quantity, cylinder count, verified bank charge and release-time capability, then use Advanced for multiple protected spaces, selector and sealing readiness, alarms, maintenance, hydrostatic testing and service planning.

Figures represent Currency
↑
Need much more depth? Click Advanced above.Advanced adds protected-space rows, low-pressure storage, alarms, selector/sealing status, maintenance, hydrostatic-test scope, hose age, valve inspection and service cost.
Fast10 primary inputs
Core answerMass + bottles + release time
VisualBank coverage + discharge curve

Single Protected Space

For machinery spaces, enter both the reduced-casing volume and the entire volume including casing. Starting-air receiver free-air volume is added to the machinery-space gross-volume bases.

m³, machinery basis.
m³.
m³ free air, machinery only.
kg.
% of nominal.
kg/min.

Vessel & Storage Basis

kg.
% above statutory minimum, planning only.
Fixed FSS conversion: 0.56 m³ free CO₂ per kg.

Protected-Space Register

Each row is calculated independently; the largest required mass governs the shared bank. Space names are not sent through Tool Data.

SpaceCategoryReduced m³Full m³Air rec. m³AccessibleCustom gas %Custom frac %Custom minReq. kgCyl.

Bank Charge, Release & Controls

kg/min.
seconds.

Release Controls & Operational Readiness

Maintenance & Service

years.
years, max 10 in this screen.

Service Campaign Cost

%.
Fire-safety limitation: This tool does not size piping, nozzles, manifolds, orifices or selector valves; prove agent distribution; authorize release; or replace approved hydraulic calculations, vessel fire-control plans, flag/class approval, manufacturer instructions, SMS, surveyor or competent service technician. CO₂ is lethal to personnel.
By the ShipUniverse Editorial Team — About Us | Contact