Ship Motor Starting Current, Voltage Dip & Generator Capacity Tool
Screen shipboard motor starts against the actual generator bank instead of comparing motor kW with generator kW. Simple mode estimates starting current, locked-rotor kVA, initial bus-voltage dip and generator requirement. Advanced models multiple motors, start overlap, multiple generator sets, equivalent subtransient source strength, N-1 operation, voltage-squared torque retention and start-sequence risk.
Motor Start
Generator Bank
System Limits & Starting Study
Generator Register
Equivalent source strength is calculated from each online generator's kVA and entered Xdʺ. Pre-start load is shared in proportion to online kVA.
| Use | Available? | Name | Rated kVA | Xdʺ % | Pre-start load % |
|---|
Motor Starting Sequence
Start time and acceleration duration allow overlapping starts. Enter the effective starting-current multiple produced by the actual starter. The method label is descriptive; the entered current multiple controls the calculation.
| Use | Motor / load | kW | Rated A | Run PF | Method | Start × FLA | Start PF | Start at s | Accel s | Min bus V % | Essential? |
|---|