Starting Air • 12C / 6C Class Screen • Receiver Volume • Pressure Decay • Compressor FAD • One-Hour Recharge • Low-Pressure Alarm • N-1 Recovery

Starting Air Receiver & Compressor Tool Main Engine Starts, Bottle Volume & Recharge Time

Size and screen a marine starting-air system from the engine-start requirement through receiver storage and compressor recovery. Simple mode answers how many starts the installed bottles support, the minimum receiver volume, and recharge time. Advanced adds multiple receivers, connected pneumatic consumers, compressor redundancy, independently driven capacity, one-bottle isolation, low-pressure alarm reserve and live start-by-start pressure and recharge curves.

Figures represent
Need individual bottles, compressor redundancy, other air users or alarm reserve? Click Advanced above.Simple uses free-air-equivalent engine start consumption and an isothermal ideal-gas storage screen. Class/flag/OEM-approved values should replace the sample inputs.
EnduranceStarts before Pmin
SizingMinimum bottle volume
RecoveryOperational & full recharge

Engine Starting Requirement

m³ free air per start at atmospheric/reference condition.
m³ free air reserved for other users.

Receivers & Compressors

m³ geometric volume.
bar(g).
bar(g), OEM/approved minimum.
m³/h free-air delivery.

Starting Requirement & Thermodynamic Basis

For Z = 6 + 3(k−1), k capped at 3.
m³ free air/start, preferably OEM or measured.
% added to required free-air quantity.
bar(g).
bar(g).
bar(g).
bar absolute.
°C.
°C used in ideal-gas storage screen.

Starting-Air Receiver Register

Current class practice commonly requires at least two starting-air receivers of approximately equal capacity. The total active volume is used for the start-endurance calculation; an automatic one-largest-bottle-out screen is shown separately.

UseReceiver volume m³Status

Other Pneumatic Consumers

Connected auxiliary starting, control, whistle or essential pneumatic demand should not reduce the required engine-start reserve. Enter one-time reserve quantities and/or continuous free-air demand during compressor recovery.

UseConsumer typeReserve free air m³Continuous demand m³/h

Starting-Air Compressor Register

FAD is free-air delivery at the compressor reference/inlet condition. The class-rule screen checks total one-hour recovery, number of compressors, and independently driven capacity.

UseFAD m³/hDriveAvailable now?

Black-Start / Emergency Compressor

Starting-Air System Checks

Rule / engineering limitation: the 12C/6C and one-hour compressor screens implemented here are a current classification-rule basis for conventional reciprocating propulsion arrangements, not a substitute for the vessel’s actual class, flag and engine-maker requirements. Unusual propulsion/shafting arrangements, gas turbines, ice-class additions, control-air integration and manufacturer-specific start sequences can require different capacities.