SOLAS IV/13 β€’ 1 h / 6 h Reserve β€’ Radio Load β€’ C1 / C6 Capacity β€’ 40% Life-Cycle Allowance β€’ Charger 10 h Recovery β€’ Voltage Drop β€’ Emergency Endurance

GMDSS Reserve Battery Tool Radio Load, Capacity, Charger & Emergency Endurance

Size and screen the GMDSS reserve battery from the actual radio load instead of relying only on nameplate amp-hours. Simple mode converts receive/transmit duty into reserve current, applies the 1-hour or 6-hour SOLAS basis, rapid-discharge capacity effects, battery condition and charger recovery. Advanced builds a full reserve-bus load register, handles simultaneous versus alternative radio paths, checks current-condition endurance, life-cycle sizing, charger recovery, peak-current cable voltage drop and multiple reserve scenarios.

Figures represent
↑
Need individual radios, duplicated/alternative paths and voltage-drop checks? Click Advanced above.Simple uses the SOLAS/IMO reserve-load concept with a user-entered transmit duty factor and a 40% life-cycle sizing allowance.
Reserve1 h or 6 h endurance
CapacityUsable vs nameplate Ah
Recovery10 h charger screen

Reserve Load & Battery

β€œAdequate” means the applicable emergency source can operate radiocommunications for the required 18 h cargo / 36 h passenger period.
V DC.
A for radios/inputs that remain connected.
A maximum transmit-current basis.
% of transmit current added to receive current. 50% is the IMO general reserve-load formula.
A, e.g. required emergency light / navigation-data inputs.
Ah at the selected nameplate rating basis.
% remaining after state-of-charge, ageing and temperature effects.
A available for battery recharge.

SOLAS Reserve Duration & Battery Bank

h available from the ship’s emergency source to radiocommunications.
V DC.
Ah.
% of nameplate capacity available at the required discharge period when custom is selected.
%.
% of new-battery capacity retained.
% from manufacturer data / engineering basis.
% added to the bare minimum calculated capacity.
IMO guidance: capacity check interval should not exceed 12 months.

Reserve-Bus Radio / Essential Load Register

Average reserve current per row = quantity Γ— (receive/standby current + transmit duty factor Γ— transmit current). β€œAlternative” rows with the same group are treated as mutually exclusive and only the largest group load is counted. Use β€œSimultaneous” for loads connected at the same time. The default 50% transmit factor follows the IMO general reserve-load formula; change it only where the applicable equipment/flag calculation basis supports another duty factor.

UseLoad typeQtyRx / standby ATx max ATx duty %Demand modeAlt group

Automatic Charger & DC Distribution

A.
% used for recharge-time screen.
h; IMO guidance uses 10 h.
m for voltage-drop formula.
mmΒ².
V, user/manufacturer limit.

Survey / Installation Checks

Engineering / regulatory limitation: this tool screens a GMDSS reserve-battery installation from entered electrical data. Actual compliance depends on the ship’s SOLAS applicability, flag-State interpretation, approved equipment, manufacturer C1/C6 performance, battery chemistry, temperature, battery condition, charger configuration and verified radio load. Use approved battery-capacity calculations and survey documentation as controlling.